Output voltage: single-phase voltage: 0-150V/0-300V continuously adjustable |
||||||||||
Output frequency: 60HZ, 50HZ, 40-499.9HZ continuously adjustable |
||||||||||
Super counted ability, instantaneous current can withstand three times rated current |
||||||||||
A one click shutdown function, the reaction rate is fast, the reaction time is less than 2ms |
||||||||||
With over current, over voltage, over temperature, short circuit, overload and other multiple protection and alarm function. |
||||||||||
High precision frequency stabilized voltage stabilizing function, fast regulating voltage, frequency |
||||||||||
The main components are imported brands, quality and reliable |
||||||||||
Three out of three variable frequency power supply technical parameters |
||||||||||
model |
||||||||||
three-phaseDDBP-10 |
three-phaseDDBP-15 |
three-phaseDDBP-20 |
three-phaseDDBP-30 |
three-phaseDDBP-45 |
three-phaseDDBP-60 |
three-phaseDDBP-75 |
three-phaseDDBP-100 |
three-phaseDDBP-150 |
||
Output capacity(KVA) |
||||||||||
10 |
15 |
20 |
30 |
45 |
60 |
75 |
100 |
150 |
||
Circuit mode |
IGBT/PWM-delta modulation technique |
|||||||||
AC input |
||||||||||
Phase number |
three-phase |
|||||||||
wave form |
SINEWAWE |
|||||||||
Voltage |
380V±15% |
|||||||||
Frequency range |
50HZ or 60HZ±15% |
|||||||||
power factor |
﹥0.9 |
|||||||||
AC output |
||||||||||
Phase number |
three-phase |
|||||||||
wave form |
SINE WAVE |
|||||||||
Low voltage |
Single phase voltage: 0-150V continuously adjustable
|
|||||||||
High voltage |
Single phase voltage: 0-300V continuously adjustable |
|||||||||
frequency |
60HZ,50HZ,40-499.9HZ Continuously adjustable |
|||||||||
Frequency stability |
≤0.01% |
|||||||||
Low maximum current(A) |
||||||||||
27.8 |
41.7 |
55.6 |
83.8 |
125 |
166.7 |
208.3 |
276 |
416 |
||
High grade maximum current(A) |
||||||||||
13.9 |
20.8 |
27.8 |
41.7 |
62.5 |
83.3 |
104.2 |
138 |
208 |
||
Whole machine performance |
||||||||||
Power supply voltage |
﹤1% |
|||||||||
load regulation |
﹤1% |
|||||||||
Waveform distortion |
﹤1% |
|||||||||
efficiency |
﹥90% |
|||||||||
reaction time |
≤2ms |
|||||||||
crest factor |
3:1 |
|||||||||
Protector |
With over voltage, over current, overload, input under voltage, over temperature, short circuit and other multiple protection |
|||||||||
display |
||||||||||
Display interface |
Digital LED display |
|||||||||
Voltage |
4 digit, digital voltmeter, resolution 0.1V |
|||||||||
electric current |
4 digit, digital current meter, resolution 0.1A |
|||||||||
power |
4 digit digital watt meter |
|||||||||
frequency |
4 digit, digital frequency table |
|||||||||
Environment and other |
||||||||||
cooling system |
High speed variable frequency fan cooling, forced air cooling |
|||||||||
working temperature |
-10℃ to 50℃ |
|||||||||
relative humidity |
0~90%(non-condensing) |
|||||||||
Altitude |
≤1500m |
|||||||||
weight(KG) |
||||||||||
200 |
260 |
320 |
450 |
550 |
660 |
750 |
900 |
1350 |
||
size(H*D*W)mm |
|
|
|
|
||||||
850*650*500 |
1100*750*550 |
1310*800*600 |
1400*1100*800 |
1500*1200*1000 |
||||||
Note: more than 1 of the size does not contain the height of the foot |
||||||||||